Instructions
Electrical / Electrical Systems / Door Control System / DA-RM-07M002-02-001 - Remove/Install switch - Door release - External
Preparation work
1.     
2.     
Care Point: Lower the Glass - Door 150mm from the upper edge of the door frame before disconnecting the battery.
3.     
4.     
5.     
6.     
Care Point: Remove the upper loudspeaker only.
7.     
Care Point: Disconnect only.
8.     
Care Point: Disconnect only.
9.     
10.    
11.    
12.    
13.    

Remove switch - Door release - External
 
Care Point:
Protect the surrounding area.

 
1.  
Remove bolts (1).(M6x40) 6 Nm
 
2.  
Release winglet (2) from the adhesive pads (3).
 
 
Care Point:
Guide door switch wiring harness through winglet.

 
3.  
Loosen nut and remove door switch from winglet.0.5 Nm
 


Install switch - Door release - External
 
Care Point:
Remove excess adhesive.

Care Point:
Clean adhesive mounting area using Betaclean 3900.

Care Point:
Replace the adhesive tape.3M PT1100

 
1.  
Install components in reverse order.
 
 
Care Point:
The procedure below must be claimed separately if you make a warranty claim.

 
2.  
Check camera alignment, adjust if required.DA-RM-07M021-00-001 - Calibrate 360 camera system
 

   
   
   Note